HA System Configuration Mismatch Alarm
This alarm is applicable only to products supporting HA (Mediant 500, Mediant 800, Mediant 2600, Mediant 4000, Mediant 9000, and Mediant Software).
acHASystemConfigMismatchAlarm
Alarm |
acHASystemConfigMismatchAlarm |
||
---|---|---|---|
OID |
1.3.6.1.4.1.5003.9.10.1.21.2.0.34 |
||
Description |
The alarm is sent when the License Keys of the two units in the High Availability (HA) system is not identical, causing instability. |
||
Default Severity |
Major |
||
Source Varbind Text |
System#0/Module#<m>, where m is the blade module’s slot number |
||
Event Type |
processingErrorAlarm |
||
Probable Cause |
configurationOrCustomizationError |
||
Severity |
Condition |
Text |
Corrective Action |
Major |
License Keys of Active and Redundant units are different. |
"Configuration mismatch in the system: Active and Redundant modules have different feature keys." |
Update the License Keys of the Active and Redundant units. |
The Active unit was unable to pass on to the Redundant unit the License Key. |
"Configuration mismatch in the system: Fail to update the redundant with feature key." |
Replace the License Key of the Redundant unit because it may be invalid. |
|
License key of the Redundant unit is invalid. |
"Configuration mismatch in the system: Feature key did not update in redundant module." |
Replace the License Key of the Redundant unit because it may be invalid. |
|
Cleared |
Successful License Key update |
"The feature key was successfully updated in the redundant module" |
- |